Opening pressure compensator
The pressure compensator represents a pressure dependent hydraulic resistance. The pressure compensator opens when the pressure difference X-Y exceeds the nominal pressure. A pressure relief valve is implemented by the combination of connections P and X. The pressure balance is also a component of 3-way flow control valves.
The nominal pressure setting of the real components is component dependent and cannot be changed.
The hydraulic resistance relates to the completely opened valve.
Adjustable parameters
| Designation | Range | Default value |
|---|---|---|
| Nominal pressure | 0 ... 40 MPa | 1 |
| Pressure regulation range | 0.01 ... 10 MPa | 0.2 |
| Hydraulic resistance | 1e-6 ... 1000 bar.min2/l2 | 0.1 |