Pressure relief valve
In normal position the valve is closed. If the opening pressure is reached at P, T opens. When the pressure drops below the preset level, the valve closes again. The flow direction is indicated by the arrow.
The hydraulic resistance relates to the completely opened valve.
Adjustable parameters
Designation | Range | Default value |
---|---|---|
Opening pressure | 0 ... 40 MPa | 3 |
Pressure regulation range | 0.01 ... 10 MPa | 3.8 |
Hydraulic resistance | 1e-6 ... 1000 bar.min2/l2 | 0.17 |
Failure models
Failure model | Description |
---|---|
Linear scaling | Instead of the nominal value u the lineal scaling y = slope_err*u+ offset_err is used. |
Designation | Range | Default value |
---|---|---|
Offset | -40 ... 40 MPa | 0 |
Slope | 0 ... 10 | 0.5 |