Variable closing pressure compensator

The pressure compensator represents a pressure dependent hydraulic resistance. The pressure compensator closes when the pressure difference X-Y exceeds the nominal pressure. A pressure regulating valve is implemented by the combination of the connections A and X.

The hydraulic resistance relates to the completely opened valve.

Adjustable parameters

Designation Range Default value
Nominal pressure 0 ... 40 MPa 1
Pressure regulation range 0.01 ... 10 MPa 0.2