Closing pressure compensator
The pressure compensator represents a pressure dependent hydraulic resistance. The pressure compensator closes when the pressure difference X-Y exceeds the nominal pressure. A pressure regulating valve is implemented by the combination of connections A and X. The pressure balance is also a component of 2-way flow control valves.
The nominal pressure setting of the real components is component dependent and cannot be changed.
The hydraulic resistance relates to the completely opened valve.
Adjustable parameters
Designation | Range | Default value |
---|---|---|
Nominal pressure | 0 ... 40 MPa | 1 |
Pressure regulation range | 0.01 ... 10 MPa | 0.2 |
Hydraulic resistance | 1e-6 ... 1000 bar.min2/l2 | 0.1 |