Opening pressure compensator

The pressure compensator represents a pressure dependent hydraulic resistance. The pressure compensator opens when the pressure difference X-Y exceeds the nominal pressure. A pressure relief valve is implemented by the combination of connections P and X. The pressure balance is also a component of 3-way flow control valves.

The nominal pressure setting of the real components is component dependent and cannot be changed.

The hydraulic resistance relates to the completely opened valve.

Adjustable parameters

Designation Range Default value
Nominal pressure 0 ... 40 MPa 1
Pressure regulation range 0.01 ... 10 MPa 0.2
Hydraulic resistance 1e-6 ... 1000 bar.min2/l2 0.1