3-way pressure regulator

The pressure reducing valve maintains a constant output pressure despite fluctuating input pressure. The hydraulic fluid is drained off at T when the pressure at connection A exceeds the operating pressure.

The hydraulic resistance relates to the completely opened valve.

Adjustable parameters

Designation Range Default value
Nominal pressure 0 ... 40 MPa 3
Pressure regulation range 0.01 ... 10 MPa 1.9
Hydraulic resistance 1e-6 ... 1000 bar.min2/l2 0.1