4/2-way solenoid valve (ii)
In normal position the connection P is open to A and B to T. When actuated by the control solenoid, the valve is set to crossover position. If no current is flowing through the control solenoid, the valve can be manually actuated.
This valve is derived from a configurable 4/n way valve. You find this valve in the component library Frequently used Way Valves
, under the menu.
Adjustable parameters
Designation |
Range |
Default value |
Desired position |
0 ... 4 |
0 |
Hydraulic resistance |
1e-6 ... 1000 bar.min2/l2 |
0.164 |
Positioning time |
1e-4 ... 10 s |
0.02 |
Reset time |
1e-4 ... 10 s |
0.03 |
Acting forces
Designation |
Range |
Default value |
Minimum voltage |
0.1 ... 300 V |
20 |
Electrically left at U_min |
0.01 ... 100 N |
70 |
Electrically right at U_min |
0.01 ... 100 N |
70 |
Mechanically left |
0.01 ... 100 N |
100 |
Mechanically right |
0.01 ... 100 N |
100 |
Counteracting forces
Designation |
Range |
Default value |
Physical spring force |
0.01 ... 100 N |
30 |
Minimum force |
0.01 ... 100 N |
20 |
Min. pilot control force |
0.01 ... 100 N |
15 |
Effective areas
Designation |
Range |
Default value |
Left |
0.01 ... 100 cm2 |
1 |
Right |
0.01 ... 100 cm2 |
1 |
Pilot control left |
0.01 ... 100 cm2 |
1 |
Pilot control right |
0.01 ... 100 cm2 |
1 |
Failure models
Failure model |
Description |
Piston blocked |
The valve can not change its switching position. |
All ports connected in position 2 |
In switching position 2 all connectors are internally connected. |