4/n Way Valve
Adjustable parameters
| Designation |
Range |
Default value |
| Desired position |
0 ... 4 |
0 |
| Hydraulic resistance |
1e-6 ... 1000 bar.min2/l2 |
0.164 |
| Positioning time |
1e-4 ... 10 s |
0.02 |
| Reset time |
1e-4 ... 10 s |
0.03 |
Acting forces
| Designation |
Range |
Default value |
| Minimum voltage |
0.1 ... 300 V |
20 |
| Electrically left at U_min |
0.01 ... 100 N |
70 |
| Electrically right at U_min |
0.01 ... 100 N |
70 |
| Mechanically left |
0.01 ... 100 N |
100 |
| Mechanically right |
0.01 ... 100 N |
100 |
Counteracting forces
| Designation |
Range |
Default value |
| Physical spring force |
0.01 ... 100 N |
30 |
| Minimum force |
0.01 ... 100 N |
20 |
| Min. pilot control force |
0.01 ... 100 N |
15 |
Effective areas
| Designation |
Range |
Default value |
| Left |
0.01 ... 100 cm2 |
1 |
| Right |
0.01 ... 100 cm2 |
1 |
| Pilot control left |
0.01 ... 100 cm2 |
1 |
| Pilot control right |
0.01 ... 100 cm2 |
1 |
Failure models
| Failure model |
Description |
| Piston blocked |
The valve can not change its switching position. |
| All ports connected in position 2 |
In switching position 2 all connectors are internally connected. |