4/2-way hand-lever valve (ii)
In normal position the connection P is open to A and B to T. When manually actuated the valve is set to crossover position.
This valve is derived from a configurable 4/n way valve. You find this valve in the component library Frequently used Way Valves
, under the menu.
Adjustable parameters
Designation |
Range |
Default value |
Desired position |
0 ... 4 |
0 |
Hydraulic resistance |
1e-6 ... 1000 bar.min2/l2 |
0.164 |
Positioning time |
1e-4 ... 10 s |
0.02 |
Reset time |
1e-4 ... 10 s |
0.03 |
Acting forces
Designation |
Range |
Default value |
Minimum voltage |
0.1 ... 300 V |
20 |
Electrically left at U_min |
0.01 ... 100 N |
70 |
Electrically right at U_min |
0.01 ... 100 N |
70 |
Mechanically left |
0.01 ... 100 N |
100 |
Mechanically right |
0.01 ... 100 N |
100 |
Counteracting forces
Designation |
Range |
Default value |
Physical spring force |
0.01 ... 100 N |
30 |
Minimum force |
0.01 ... 100 N |
20 |
Min. pilot control force |
0.01 ... 100 N |
15 |
Effective areas
Designation |
Range |
Default value |
Left |
0.01 ... 100 cm2 |
1 |
Right |
0.01 ... 100 cm2 |
1 |
Pilot control left |
0.01 ... 100 cm2 |
1 |
Pilot control right |
0.01 ... 100 cm2 |
1 |
Failure models
Failure model |
Description |
Piston blocked |
The valve can not change its switching position. |
All ports connected in position 2 |
In switching position 2 all connectors are internally connected. |