Proportional valve solenoid, position controlled

In FluidSIM the proportional valve solenoid is coupled to the respective continuous directional valve with the help of a label. The required slide position is predetermined via a voltage signal. The valve slide distance is position controlled. The control and amplifier component is integrated in the valve.

Adjustable parameters

Designation Range Default value
Current (max) 0.01 ... 10 A 0.1
Resistance 1 ... 10000 Ohm 128
Minimum voltage 0.1 ... 300 V 20