Wiping Relay - Pulse Output
An input signal generates a signal of specified length at the output.
The output status is switched to Hi
after the input Trg is set to Hi
. The configured time is started at the same time and the output remains set. After expiration of the configured time, the output is reset to the status Lo
(pulse output). If the input status changes from Hi
to Lo
before the specified time has expired, also the output follows immediately with a with a Hi
to Lo
transition.
Adjustable parameters
Designation | Range | Default value |
---|---|---|
Delay time | 0 ... 100 s | 3 |