Pushbutton (break)
Switch that opens when actuated and closes immediately when released.
In FluidSIM switches can be actuated permanently (locked) when continuing to hold down the mouse button and pushing the Shift key. This permanent actuation is released by a simple click on the component.
A failure model can be selected for the symbol.
Adjustable parameters
Designation | Range | Default value |
---|---|---|
State | 0 ... 1 | Inactive |
Failure models
Failure model | Description |
---|---|
Short circuit | The lamp causes a short circuit. |
Current interrupted | The line is interrupted and current cannot flow. |