Signal converter
The signal converter converts analogue voltage output signals from a sensor into switching points. It closes or opens one of the two circuits (Out A, Out B) when the adjustable switching points are reached. Possible switching functions are threshold value, hysteresis or window comparator. The switching characteristic (N/C, N/O) can also be selected.
Adjustable parameters
Out A (4)
Designation |
Range |
Default value |
Output function |
Make switch, Break switch |
Make switch |
Switching function |
Threshold value, Window comparator |
Threshold value |
Switching point 1 |
-100 ... 100 V |
1 |
Switching point 2 |
-100 ... 100 V |
8 |
Hysteresis |
0 ... 100 V |
0 |
Out B (2)
Designation |
Range |
Default value |
Output function |
Make switch, Break switch |
Make switch |
Switching function |
Threshold value, Window comparator |
Threshold value |
Switching point 1 |
-100 ... 100 V |
1 |
Switching point 2 |
-100 ... 100 V |
8 |
Hysteresis |
0 ... 100 V |
0 |
Designation |
Range |
Default value |
Switching time |
1e-5 ... 10 s |
0.001 |
Minimum voltage |
1 ... 300 V |
15 |
Idle current (24 V) |
1 ... 10000 mA |
32 |