OR
The output Q is only set to 1 if there is a 1 at a minimum of one input (A, B). The standard symbol has two inputs. Extended symbols can have more than two inputs.
Truth table
A | B | Q |
---|---|---|
0 | 0 | 0 |
0 | 1 | 1 |
1 | 0 | 1 |
1 | 1 | 1 |
The IC 74HC32 is used as a component in the training package TP 1012 from Festo Didactic.
Adjustable parameters
Designation | Range | Default value |
---|---|---|
Voltage level (lo) | 0.1 ... 24 V | 0.8 |
Voltage level (hi) | 0.1 ... 24 V | 2 |
Designation | Range | Default value |
---|---|---|
Voltage level (lo) | 0 ... 24 V | 0 |
Voltage level (hi) | 0.1 ... 24 V | 5 |
Resistance | 0.1 ... 1000 Ohm | 45 |