Limiter

The limiter is a closed-loop control technology component. Within a defined voltage range, the input signal/potential at input 1 is replicated to another defined voltage range of the output signal/potential. In order to keep circuit wiring as straightforward as possible, required earthing (0 V) and supply voltage are not led out as terminals, but rather wired internally.

The voltage range of the input and output signals are specified after selecting the Operating mode option.

Adjustable parameters

Designation Range Default value
Operating mode In [-10 V..10 V] —> Out [0 V..10 V], In [-10 V..10 V] —> Out [-10 V..10 V], Enter manually In [-10 V..10 V] —> Out [0 V..10 V]
Min. Voltage (in) -400 ... 400 V -10
Max. Voltage (in) -400 ... 400 V 10
Min. Voltage (out) -400 ... 400 V -10
Max. Voltage (out) -400 ... 400 V 10