Pressure switch, automotive specific
The switch closes when the preset pressure is exceeded. The current pressure can only be set by clicking with the mouse during simulation. It is not possible to access a real pressure within a pneumatic or hydraulic circuit.
Adjustable parameters
Designation | Range | Default value |
---|---|---|
Input pressure | -1 ... 1000 bar | 0 |
Output function | Make switch, Break switch | Make switch |
Switching function | Threshold value, Window comparator | Threshold value |
Switching pressure 1 | -1 ... 1000 bar | 30 |
Switching pressure 2 | -1 ... 1000 bar | 40 |
Hysteresis | 0 ... 1000 bar | 0 |
Failure models
Failure model | Description |
---|---|
Component does not switch | The component is always switched off. |
Component always switches | The component is always switched on. |
Faulty switching value | The component switches at a faulty value. |
Designation | Range | Default value |
---|---|---|
Switching pressure 1 | -1 ... 1000 bar | 3 |
Switching pressure 2 | -1 ... 1000 bar | 10 |
Hysteresis | 0 ... 1000 bar | 0 |