Flush valve with pressure relief valve

If differential pressure exceeds the required force for the spring, the valve opens from B to the pressure-relief valve.

The pressure-relief valve assures that pressure on the suction side does not drop to below the required minimum pressure for the pump.

Adjustable parameters

Directional valve
Designation Range Default value
Spring preload 0 ... 40 MPa 0.25
Hydraulic resistance 1e-6 ... 1000 bar.min2/l2 0.08
Pressure control valve
Designation Range Default value
Opening pressure 0 ... 40 MPa 0.5
Hydraulic resistance 1e-6 ... 1000 bar.min2/l2 0.08