Counterbalance valve

The valve limits pressure at port P vis-à-vis pressure applied to T to the selected value.

Adjustable parameters

Pressure control valve
Designation Range Default value
Opening pressure 0 ... 40 MPa 3.0
Pressure regulation range 0.01 ... 10 MPa 1
Hydraulic resistance 1e-6 ... 1000 bar.min2/l2 0.1
Area ratio 0.1 ... 10 3
Non-return valve
Designation Range Default value
Hydraulic resistance 1e-6 ... 1000 bar.min2/l2 0.1