Diaphragm accumulator with shutoff block

Stores the pressure and is equipped with a pressure relief valve to prevent overpressure.

Adjustable parameters

Reservoir
Designation Range Default value
Pre-load pressure 0 ... 40 MPa 1
Volume 0.01 ... 100 l 0.32
Pressure relief valve
Designation Range Default value
Opening pressure 0 ... 35 MPa 8

See also