Flow meter
The flow meter consists of a hydraulic motor connected to an RPM gauge.
In addition to the measurement of speed in rpm via direct contact with the motor shaft, revolutions can also be counted with the help of an opto-electrical sensor.
Adjustable parameters
Designation | Range | Default value |
---|---|---|
Displacement | 0.1 ... 5000 cm3 | 8.2 |
Friction | 0.001 ... 100 N.m.s/rad | 0.0108 |
Moment of inertia | 0.0001 ... 10 kg.m2 | 0.0001 |
Leakage | 0 ... 10 l/(min.bar) | 0.0126 |
Pulses per revolution | 0 ... 20 | 3 |
Designation | Range | Default value |
---|---|---|
Flow Direction | Ignore, Consider | Ignore |
Flow rate (min) | -500 ... 500 l/min | 0 |
Flow rate (max) | -500 ... 500 l/min | 10 |
Voltage (q1) | -100 ... 100 V | 0 |
Voltage (q2) | -100 ... 100 V | 10 |