Throttle check valve

The one-way flow control valve is made up of a throttle valve and a check valve. The check valve stops the flow from passing in a certain direction. The flow then passes though the throttle valve. The cross-section of the throttle is adjustable via a regular screw. In the opposite direction the flow can pass through the check valve.

Adjustable parameters

Flow control valve
Designation Range Default value
Opening level 0 ... 100 % 100
Standard nominal flow rate 0.1 ... 5000 l/min 85
Non-return valve
Designation Range Default value
Standard nominal flow rate 0.1 ... 5000 l/min 110

Failure models

Failure model Description
Check valve always closed The check valve is always closed.
Check valve always open The check valve is always open.