Throttle check valve
The one-way flow control valve is made up of a throttle valve and a check valve. The check valve stops the flow from passing in a certain direction. The flow then passes though the throttle valve. The cross-section of the throttle is adjustable via a regular screw. In the opposite direction the flow can pass through the check valve.
Adjustable parameters
Designation | Range | Default value |
---|---|---|
Opening level | 0 ... 100 % | 100 |
Standard nominal flow rate | 0.1 ... 5000 l/min | 85 |
Designation | Range | Default value |
---|---|---|
Standard nominal flow rate | 0.1 ... 5000 l/min | 110 |
Failure models
Failure model | Description |
---|---|
Check valve always closed | The check valve is always closed. |
Check valve always open | The check valve is always open. |