5/2-way solenoid impulse valve
The solenoid valve is controlled by applying a voltage signal at the solenoid coil (flow passes from 1 to 4) and remains in this operating position even when the signal is cut off. Only by applying an opposite signal will the valve return to its starting position (flow passes freely from 1 to 2). If no signal is applied to the valve, it can be manually operated.
This valve is derived from a configurable 5/n way valve. You find this valve in the component library Frequently used Way Valves
, under the menu.
Adjustable parameters
Designation |
Range |
Default value |
Desired position |
0 ... 4 |
0 |
Standard nominal flow rate |
0.1 ... 5000 l/min |
60 |
Positioning time |
1e-4 ... 10 s |
0.02 |
Reset time |
1e-4 ... 10 s |
0.03 |
Acting forces
Designation |
Range |
Default value |
Minimum voltage |
0.1 ... 300 V |
20 |
Electrically left at U_min |
0.01 ... 100 N |
70 |
Electrically right at U_min |
0.01 ... 100 N |
70 |
Mechanically left |
0.01 ... 100 N |
100 |
Mechanically right |
0.01 ... 100 N |
100 |
Counteracting forces
Designation |
Range |
Default value |
Physical spring force |
0.01 ... 100 N |
20 |
Minimum force |
0.01 ... 100 N |
15 |
Min. pilot control force |
0.01 ... 100 N |
15 |
Effective areas
Designation |
Range |
Default value |
Left |
0.01 ... 100 cm2 |
1 |
Right |
0.01 ... 100 cm2 |
1 |
Pilot control left |
0.01 ... 100 cm2 |
1.3 |
Pilot control right |
0.01 ... 100 cm2 |
1.3 |
air spring left |
0.01 ... 100 cm2 |
0.5 |
air spring right |
0.01 ... 100 cm2 |
0.5 |
Failure models
Failure model |
Description |
Piston blocked |
The valve can not change its switching position. |
Mid-position pressurized |
The valve acts like the following one: 5/3-way valve, pneumatically actuated in both directions, mid-position pressurized |