Air service unit

The service unit is made up of a compressed air filter with water separator and a pressure control valve.

Adjustable parameters

Pressure regulator
Designation Range Default value
Nominal pressure 0 ... 2 MPa 0.4
Standard nominal flow rate 0.1 ... 5000 l/min 750
Filter
Designation Range Default value
Standard nominal flow rate 0.1 ... 5000 l/min 1000

Failure models

Failure model Description
Component clogged The component is clogged. The restricted flow can be adjusted.
Parameter
Designation Range Default value
Standard nominal flow rate 0 ... 5000 l/min 10