Two-hand control block
The control block for two-hand start ZSB is a pneumatic AND element.
If the inputs 11 and 12 are pressurized within max. 0.5 s one after the other, the ZSB will switch through: an output signal is present at port 2. Control takes place via two external 3/2-way pushbutton valves.
As long as both pushbutton valves are activated, outlet port 2 is pressurized. If one or both pushbuttons are released, outlet port 2 is unpressurized. The system exhausts from 2 to 3.
Adjustable parameters
Designation | Range | Default value |
---|---|---|
Opening level | 0 ... 100 % | 100 |
Standard nominal flow rate | 0.1 ... 5000 l/min | 50 |